In addition to the usual site and services data the following information is needed in order to allow a multiphase pump selection to be made;

 Field Parameters and Pump Selection

  • Standard Gas Oil Ratio (GOR at standard conditions)
scft/bbl Nm3/m3
  • Oil flowrate at pump inlet
bbl/day m3/h
  • Actual gas flowrate at pump inlet
scft/day
  • Water Cut (WC), or
  • Water flowrate at pump inlet
bbl/day m3/h
  • Desired pump inlet pressure
psig barg
  • Temperature of well stream at pump inlet
°F °C
  • Oil specific gravity
°API kg/m3
  • Required pump discharge pressure
psig barg

Your requirements may be submitted through one of our sales offices or e-mailed direct to one of the multiphase specialists listed below.

We look forward to receiving your enquiry.